![]() If at any time, a fire extinguisher shows evidence of dents, mechanical injury, or corrosion to the extent as to indicate weakness, it shall be condemned or hydrostatically tested. The extinguisher shall be emptied and subjected to the applicable internal and external examination procedures as detailed in the manufacturer’s service manual and NFPA-10. Fire extinguishers that require a hydrostatic test are pressure tested to verify its strength against unwanted leaks or ruptures. 5 & 12 Year Hydrostatic Testing– Extinguishers are hydrostatically tested every 5 & 12 years from its manufacture date.All internal parts of the extinguisher are replaced, and the dry chemical powder is recycled or replaced as necessary. ![]() Maintenance can be conducted once a year or when indicated by an inspection discrepancy. 6 Year Fire Extinguisher Maintenance– Every 6 years from its manufacture date, stored-pressure fire extinguishers that require a 12-year fire extinguisher hydrostatic test shall be emptied and subjected to the applicable internal and external examination procedures as detailed in the manufacturer’s service manual and NFPA-10. Unlike the monthly visual inspection, fire extinguisher maintenance needs to be performed by a certified person familiar with the requirements of the NFPA 10.If any repair or replacement is necessary, and if hydrostatic testing or internal maintenance is required, DynaFire staff will service accordingly. A thorough examination of the extinguisher determines if physical damage or condition will prevent its operation. All rechargeable H3R Aviation fire extinguishers require a 12 year hydrostatic test performed by a certified technician per NFPA 10. Annual Fire Extinguisher Maintenance– Annual fire extinguisher maintenance is intended to give maximum assurance that extinguishers will effectively operate. Visual Fire Extinguisher Inspections Once per Month According to OSHA.High & low-pressure hydrostatic testing of all fire extinguishers.Ĭommercial Fire Extinguisher Signs, Labels, & Tags Service/maintenance is a detailed examination of the portable fire extinguisher. The National Fire Protection Association requires that. We offer all major extinguisher brands & types: Ansul, Buckeye, Amerex, & BadgerĪBC, BC, Purple K, CO2, K-Class, Halotron, Water Mist, Water, Class D, FE-36, High Flow, Industrial Wheeled Units, & Redline Series type fire extinguishers extinguisher is visible during a monthly inspection. Regular inspections help to make sure your fire extinguishers are dependable and ready when necessary. NFPA 10 requires a thorough annual examination of your portable fire extinguishers’ mechanical parts, extinguishing agent and expelling means by an approved fire protection service. Inspection, maintenance, and repair service as needed per manufacturer standards and NFPA 10 Call Unifour Fire & Safety at 86 to schedule your annual or six-year fire extinguisher inspection or get a free quote online. Annual Fire Extinguisher Inspection Requirements.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |